Category Archives: Uncategorized

Geiger counter – specifications

Specifications

  • Used in the fields of Physics, Chemistry, Biology and Environmental science.
  • Measures ionizing radiation on the basis of a Geiger-Mueller tube.
  • Includes a geiger counter probe.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

 

Resistance – specifications

Specifications

  • Used in the fields of Physics, Electronics, Chemistry, etc
  • Includes red (positive probe) and black (negative probe) wires connected directly to the sensor’s body . The wires are attached to 4 mm red and black plugs.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

 

Charge – specifications

Specifications

  • Used in the fields of Physics, Electronics, Chemistry, Biology, etc.
  • Houses a sensitive voltage sensor with several capacitors in series along the input. While an electric current flows through the circuit, the capacitors gain charge until they have a charge in equilibrium with the voltage level of the source.
  • Includes power and ground wires connected directly to the sensor’s body and alligator clips for both of the power and ground wires.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

 

Dew point – specifications

Specifications

  • Used in the fields of Biology, Exercise Science, Environmental Science, Earth Science, Weather Science, Botany, Entomology, etc.
  • The sensor relies on two different sensors to accurately determine the dew point of an environment: a temperature and a humidity sensor. The internal temperature sensor uses a thermistor which changes its resistance according to temperature change. The internal humidity sensor utilizes a dielectric polymer to absorb water molecules.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

 

GPS – specifications

Specifications

    • Used in the fields of Biology and Environmental science, etc.
    • The Global Positioning System (GPS) is a space-based satellite navigation system that provides location and time information in all weather conditions, anywhere on or near the Earth where there is an unobstructed line of sight to four or more GPS satellites.
    • The sensor is pre-calibrated at the factory.
    • Experiment duration: up to 11 hours

 

 

Anemometer – specifications

Specifications

  • Used in the fields of Environmental Science, Weather Science, Ecology, Biology, etc.
  • The sensor is based on a rotating magnet situated within a metal coil.
  • Includes an anemometer probe made from durable plastic, attached to the sensor’s body by a strong rubber-coated wire.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

 

Nitrate – specifications

Specifications

  • Used in the fields of Environmental Science, Ecology, Chemistry, Biology, etc.
  • Uses a permanently filled ion selective electrode to accurately measure the amount of nitrate ion in a solution.
  • Includes a nitrate sensor electrode, nitrate Ionic strength adjuster (ISA), nitrate 1000 ppm standard.
  • The sensor is pre-calibrated at the factory.
  • Offsetting is conducted by using a 10 ppm nitrate solution. Download offsetting software from the bottom of the Software and Application page.
  • Experiment duration: 1 second to 31 days.

Ammonium – specifications

Specifications

  • Used in the fields of Environmental Science, Ecology, Chemistry, Biology, etc.
  • Uses a permanently filled ion selective electrode to accurately measure the amount of ammonium ion in a solution.
  • Includes a ammonium sensor electrode, ammonium Ionic strength adjuster (ISA), ammonium 1000 ppm standard.
  • The sensor is pre-calibrated at the factory.
  • Offsetting is conducted by using a 10 ppm ammonium solution.
  • Experiment duration: 1 second to 31 days.

 

 

Chloride – specifications

Specifications

  • Used in the fields of Environmental Science, Ecology, Chemistry, Biology, etc.
  • Uses a permanently filled ion selective electrode to accurately measure the amount of chloride ion in a solution.
  • Includes a chloride sensor electrode, chloride Ionic strength adjuster (ISA), chloride 1000 ppm standard.
  • The sensor is pre-calibrated at the factory.
  • Offsetting is conducted by using a 10 ppm chloride solution.
  • Experiment duration: 1 second to 31 days.

 

 

Calcium – specifications

Specifications

  • Used in the fields of Environmental Science, Ecology, Chemistry, Biology, etc.
  • Uses a permanently filled ion selective electrode to accurately measure the amount of calcium ion in a solution.
  • Includes a calcium sensor electrode, calcium Ionic strength adjuster (ISA), calcium 1000 ppm standard.
  • The sensor is pre-calibrated at the factory.
  • Offsetting is conducted by using a 10 ppm calcium solution.
  • Experiment duration: 1 second to 31 days.