Hand dynamometer – specifications

Specifications

  • Used in the fields of Exercise science, Biology, Physiology, Psychology, etc.
  • The sensor is based on a metal rod connected at both sides to the force sensor hooks in a special shape called ‘S’ shape. A strain gauge is attached to the metal rod and connected to a very sensitive operational amplifier.
  • Includes a Hand dynamometer plastic grip attachment.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

Sensor Guide and Example labs

Respiration monitor belt – specifications

Specifications

  • Used in the fields of Exercise Science, Biology, Physiology, Human Health, etc.
  • The transducer is based on silicon between metal foils that changes its resistance according to pressure. One side of it is at complete vacuum that enables to measure the absolute pressure on its other side.
  • Includes a respiration monitor belt attached directly to the sensor by flexible rubber tubing and a hand pump with pressure release valve attached directly to the respiration monitor belt.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

Sensor Guide and Example labs

Wide range temperature – specifications

Specifications

  • Used in the fields of Physics, Chemistry, Biology, Environmental Science, etc.
  • Uses a thermocoupler to accurately measure temperatures from very cold (-200°C) to very hot (1200°C). Two wires of different compositions and thermal conductance properties are connected at the ends.
  • Includes a temperature sensor flexible probe attached by a durable rubber-coated wire to the sensor’s body.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

Sensor Guide and Example labs

Surface temperature – specifications

Specifications

  • Used in the fields of Physics, Chemistry, Biology, Environmental Science, etc.
  • Uses a 10KΩ NTC thermistor (Negative Temperature Coefficient variable resistor), which is a variable resistor that varies significantly with temperature.
  • Includes a flexible temperature probe attached by a durable rubber-coated wire to the sensor’s body.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

Sensor Guide and Example labs

UVA – specifications

Specifications

  • Used in the fields of Environmental Science, Biology, Physiology, Chemistry, Weather Science, etc.
  • Uses a special photodiode which reacts with electromagnetic radiation in the UV spectrum. An internal selective filter limits the range down to specifically the UVA range (315 to 400 nm) so only the UVA rays may pass through.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

Sensor Guide and Example labs

Turbidity – specifications

Specifications

  • Used in the fields of Chemistry, Biology, Microbiology, Earth Science, Environmental Science, Biochemistry, etc.
  • Samples are poured into cuvettes which are then placed inside the turbidity sensor for analysis. An infrared light is directed at the cuvette and it is scattered off by any suspended particles present in the sample. A photodiode positioned perpendicular to the light source loses free electrons (photoelectrons) when the scattered photons hit it, creating a readable voltage.
  • Includes Three plastic cuvettes with three lids.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

Sensor Guide and Example labs

UVB – specifications

Specifications

  • Used in the fields of Environmental Science, Biology, Physiology, Chemistry, Weather Science, etc.
  • uses a special photodiode which reacts with electromagnetic radiation in the UV spectrum. An internal selective filter limits the range down to specifically the UVB range (280 to 320 nm) so only UVB rays may pass through.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

Sensor Guide and Example labs

Soil moisture – specifications

Specifications

  • Used in the fields of Environmental Science, Ecology, Animal Behavior, Biology, Chemistry, etc.
  • Utilizes a Blumat soil moisture probe in conjunction with the NeuLog sensor’s hardware and software.
  • Includes a Blumat soil moisture probe attached directly to the NeuLog sensor’s body.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

Sensor Guide and Example labs

 

Salinity – specifications

Specifications

  • Used in the fields of Chemistry, Biology, Earth Science, Environmental Science, Biochemistry, Physics, etc.
  • An electrical potential difference is applied to the electrodes located on the salinity probe to generate a current through the solution. If ions are present, the current flows between the electrodes.
  • Includes a salinity probe which is directly attached to the sensor’s plastic body.
  • The sensor is pre-calibrated at the factory.
  • Experiment duration: 1 second to 31 days.

 

Sensor Guide and Example labs